1 Hour Fire Rated Roof Ceiling Assembly

See full report for details.
1 hour fire rated roof ceiling assembly. Rating also applies with 5 8 15 9 mm fire shield c kal kore plaster base. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Usg provides resources here for our ul wall assemblies for seamless integration into any construction project. The fire resistance rating of a wood frame assembly is equal to the sum of.
Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies. Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system. 3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete. Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring.
The addition of insulation to any one or two hour fire resistance rated. 722 6 2 1 fire resistance rating of wood frame assemblies. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies. Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr.
In floor ceiling or roof ceiling assemblies the addition or deletion of mineral wool or glass fiber insulation in the concealed space between the ceiling membrane and the floor or roof structure could possibly reduce the fire resistance rating. Generic fire rated assembly listing construction elements 1 5 hr rating 1 hour notes 1. 12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr. Urb concealed grid system and tile.
15 9 mm t g plywood floor sheathing. Assemblies include ducts dampers lighting or other fixtures in the tested assembly. Fire rated wood frame wall and floor ceiling assemblies 5 ws4 1 1 one hour fire resistive wood frame wall assembly 2x4 wood stud wall 100 design load astm e 119 nfpa 251. This section contains procedures for calculating the fire resistance ratings of walls floor ceiling and roof ceiling assemblies based in part on the standard method of testing referenced in section 703 2.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.